{{tag>[Hardware HP p222]}}
=====HP P222 configuration=====
====Show RAID config====
Add 'detail' to the command below for more detail.
# hpssacli controller slot=1 show config
Smart Array P222 in Slot 1 (sn: PDSXH0BRH6E0ZP)
array A (SAS, Unused Space: 0 MB)
logicaldrive 1 (558.7 GB, RAID 1+0, OK)
physicaldrive 2I:1:1 (port 2I:box 1:bay 1, SAS, 300 GB, OK)
physicaldrive 2I:1:2 (port 2I:box 1:bay 2, SAS, 300 GB, OK)
physicaldrive 2I:1:3 (port 2I:box 1:bay 3, SAS, 300 GB, OK)
physicaldrive 2I:1:4 (port 2I:box 1:bay 4, SAS, 300 GB, OK)
SEP (Vendor ID PMCSIERA, Model SRCv8x6G) 380 (WWID: 50014380305FB0DF)
====Show status====
# hpssacli controller slot=1 show status
Smart Array P222 in Slot 1
Controller Status: OK
Cache Status: OK
Battery/Capacitor Status: OK
====Enable drive write cache====
//CAUTION: Because physical drive write cache is not battery-backed, you could lose data if a power failure occurs during a write process. To minimize this possibility, use a backup power supply"//
* First get current cache status: # hpssacli controller slot=1 show config detail |grep -i cache
Cache Serial Number: PBKUA0BRH6E54G
Wait for Cache Room: Disabled
Cache Board Present: True
Cache Status: OK
Cache Ratio: 25% Read / 75% Write
Drive Write Cache: Disabled
Total Cache Size: 512 MB
Total Cache Memory Available: 304 MB
No-Battery Write Cache: Disabled
Cache Backup Power Source: Capacitors
Cache Module Temperature (C): 35
* Enable drive write cache: # hpssacli controller slot=1 modify dwc=enable
Warning: Without the proper safety precautions, use of write cache on physical
drives could cause data loss in the event of power failure. To ensure
data is properly protected, use redundant power supplies and
Uninterruptible Power Supplies. Also, if you have multiple storage
enclosures, all data should be mirrored across them. Use of this
feature is not recommended unless these precautions are followed.
Continue? (y/n)