{{tag>[ibm aix]}}
===== Upgrade AIX 7.1 =====
First download the ML or TL files from the IBM fix central website.
==== Note! ====
If you installed a minimal AIX (without the default to install ALL devices), then install the file sets below manually, else upgrade might fail.
devices.common.IBM.storfwork.rte
==== Create new filesystem /usr/sys/inst.images ====
mklv -t jfs2 -y instimglv datavg 5000
crfs -v jfs2 -d instimglv -m /usr/sys/inst.images -A yes
mount /usr/sys/inst.images
==== Upgrade ====
* Log in as root
* **Optional!** Rename the BFF files
bffcreate -c -d /usr/sys/inst.images
* Create TOC
inutoc /usr/sys/inst.images
* Verify currently installed software
lppchk -v
oslevel -s
* Start update (with commit and accept license). This could take up to several hours.
install_all_updates -c -Y -d /usr/sys/inst.images
* Reboot
shutdown -Fr
* Verify
lppchk -v
oslevel -s
oslevel -rl 7100-02
instfix -i | grep ML
==== Troubleshoot ====
instfix -ic | grep ":-:"