Table of Contents

, ,

HP P222 configuration

Show RAID config

Add 'detail' to the command below for more detail.

# hpssacli controller slot=1 show config

Smart Array P222 in Slot 1                (sn: PDSXH0BRH6E0ZP)

   array A (SAS, Unused Space: 0  MB)


      logicaldrive 1 (558.7 GB, RAID 1+0, OK)

      physicaldrive 2I:1:1 (port 2I:box 1:bay 1, SAS, 300 GB, OK)
      physicaldrive 2I:1:2 (port 2I:box 1:bay 2, SAS, 300 GB, OK)
      physicaldrive 2I:1:3 (port 2I:box 1:bay 3, SAS, 300 GB, OK)
      physicaldrive 2I:1:4 (port 2I:box 1:bay 4, SAS, 300 GB, OK)

   SEP (Vendor ID PMCSIERA, Model SRCv8x6G) 380 (WWID: 50014380305FB0DF)

Show status

# hpssacli controller slot=1 show status

Smart Array P222 in Slot 1
   Controller Status: OK
   Cache Status: OK
   Battery/Capacitor Status: OK

Enable drive write cache

CAUTION: Because physical drive write cache is not battery-backed, you could lose data if a power failure occurs during a write process. To minimize this possibility, use a backup power supply“